Instrument Details
Instrument/Facility Name: Atomic Absorption Spectrometer
Make                                   : Agilent 280 FS
Model                                  : Agilent 280 FS
Specification   :The Agilent 280FS AA is a fast and productive flame AA system, featuring Fast Sequential operation combined with 8-lamp capability, premium optics, and UltrAA lamp looms for greater performance.

Click to ViewThe 280FS AA features automatic lamp selection, a programmable gas box, and D2 background correction, and can be fitted with a full range of AA accessories to further extend its capabilities. Able to handle multi-element suites with ease, it is ideal for micronutrient analysis for various uses viz., environmental, food, and agriculture applications.

  Working Principles
Click to ViewAtomic absorption spectrophotometry (AAS) is used for elemental analysis of Fe, Mn, Zn, Cu, Ca, Mg, K, Se, Ni, Co, Pb and As.

  Applications
  User Instructions
Atomic absorption spectrophotometry (AAS) is one of the principal instrumen¬tal techniques for elemental analysis (Fe, Mn, Zn, Cu and some heavy metals) in most soil science laborato¬ries. In AAS, atoms excited in an oxyacetylene flame absorb light at wavelengths characteristic of each element. Light absorption is proportional to the concentration of atoms in a light path. The most commonly used radiation source is a hollow cathode lamp, consisting of a tungsten anode and a cylindrical cathode sealed in a glass tube filled with neon or argon gas. Though both single-beam and double-beam instruments are available, double- beam instruments are preferred because they minimize effects of lamp emission variations, detector sensitivity, and electronic gain. Acetylene (C2H2) as fuel and air or nitrous oxide (N20) as oxidant is commonly used. An air-Q-12 flame (2100¬-2400°C) is used for elements (such as calcium, magnesium) that do not form refractory compounds arid have low ionization potentials; an N20-C2H2 flame (2600-2800°C) is used for elements (such as aluminum) forming refractory com¬pounds. More than 60 elements can be determined by AAS. Besides detection limits, factors such as matrix or interference effects are major influences on the viability of particular analyses. Problems caused by the formation of stable compounds or compounds of low volatility by the element of interest in combination with some anion can be over¬come by the addition of an excess of a "competing cation" or a "releasing agent". For example, lanthanum (1000 mg/1) as chloride can be added in the determination of calcium and magnesium to remove the potential interference due to aluminum and phosphorus.It should be clear pre-digested liquid form.

  Contact Us
Contact No. 28466420
Email Id satishagc@iihr.res.in

  Atomic Absorption Spectrometer Charges
Procedure Name
Industry
University
National LAB/R&D
Remark
Dr. GC Satisha, Principal Scientist.
500/-
500/-
500/-

Additional Rs 100/-towards postal charges if result are to be posted
The Demand Draft should be in favour of "Director, ICAR-IIHR, Bengaluru"
Letter, DD & Samples send to "The payment should be made in advance by Demand Draft(DD) in favour of :"Director, ICAR-IIHR, Bengaluru" OR by NEFT transfer to IIHR account with following details. Beneficiary details: Indian Institute of Horticultural Research, Bank Account Number: 37578009241 , Name of the Bank : State Bank of India, Type of Account: Current Account, IFSC No.: SBIN0041187 ."