Instrument/Facility Name: CENTRIFUGE
Make                                   : Eppendorf
Model                                  : 5430R
Specification   :

Click to ViewCentrifuge 5430 R has an additional temperature control function for centrifugation between -11ºC and +40ºC use the Fast Temp function to start a temperature control run without samples to adjust the rotor chamber incl. rotor, buckets and adapters quickly to the set target temperature. This temperature control run also be started automatically at specified times using the Fast Temp pro function.

  Working Principles
Click to ViewThe particles get separated according to their size, shape, density, viscosity of the medium and rotor speed. The centrifuge involves principle of sedimentation, where the acceleration at centripetal force causes denser substances to separate out along the radial direction at the bottom of the tube

  Applications
  User Instructions
The versatile e centrifuge 5430/5430 R has a capacity of 30 × 2.0 ml and reaches max. 30.130 × g/17,000 rpm. The versatility is reflected in the available rotor options. One can select among different rotors to centrifuge the following tubes for various applications: . • Micro test tubes ( 0.2 to 2.0 ml ) • PCR strips • Falcon tubes (15 / 50 ml ) • Micro test plates • PCR plates • Deep well plates ( max. height 29 mm ) • Do not move the centrifuge while it is running. • Do not lean on the centrifuge • Do not use rotors which show any signs of corrosion and / or cracks. • Use only with rotors which have been loaded properly. Follow the instructions given in the rotor manual. • Never over load the rotor. Follow the instructions given in the rotor manual. • Never start the centrifuge when the lid is open. • Never open the lid until the rotor has come to a complete stop and this has been confirmed in the display. • Rotor installation: make sure the rotor is locked properly into place before operating the centrifuge. • Always balance the samples. Centrifuging hazardous substances: • Do not centrifuge explosive or flammable materials or substances which could react violently with one another

  Contact Us
Contact No. 0883 2449871-74
Email Id ctri-ap@nic.in

  CENTRIFUGE Charges
Procedure Name
Industry
University
National LAB/R&D
Remark

Additional Rs 100/-towards postal charges if result are to be posted
The Demand Draft should be in favour of ""
Letter, DD & Samples send to "DIRECTOR, ICAR-CTRI, Bhaskar Nagar, Rajahmundry - 533105 Andhra Pradesh, India " "