Indian Council of Agricultural Research
(Agricultural Knowledge Management Information System)


ICAR-Central Institute of Post-harvest Engineering & Technology, Post Office PAU, Behind Radha Swami Satsang Bhawan, Humbran Road, Ludhiana-141004 Punjab (www.ciphet.in)
Click Here to See Management Committee
Instrument Details
Instrument/Facility Name: GAS CHROMATOGRAPH
Make                                   : NUCON
Model                                  : 5765
Specification   :Temperature Controller / Programmer with keyboard entry of Process Parameter and Time Functions with user friendly software in ROM. Method Development facility and Electricity Failure backup. Auto Start for Temperature Programming and Data Station with one switch for reproducible Retention Time in multiple runs. Provision for upgradation for future expansion. Optional E.P.C. for the flow/ pressure of carrier gas. Provision for fixing three Injectors and three Detectors. Capable of operating two detectors simultaneously with Dual Channel Data Station. Modular in construction with option of adding Methaniser, Head Space Attachment and Manual / Auto Gas Sampling Valve. It has Non Volatile Memory for 10 Methods profiles.

Click to ViewTemperature Controller / Programmer with keyboard entry of Process Parameter and Time Functions with user friendly software in ROM. Method Development facility and Electricity Failure backup. Auto Start for Temperature Programming and Data Station with one switch for reproducible Retention Time in multiple runs. Provision for upgradation for future expansion. Optional E.P.C. for the flow/ pressure of carrier gas. Provision for fixing three Injectors and three Detectors. Capable of operating two detectors simultaneously with Dual Channel Data Station. Modular in construction with option of adding Methaniser, Head Space Attachment and Manual / Auto Gas Sampling Valve. It has Non Volatile Memory for 10 Methods profiles.

  Working Principles
Click to ViewThe sample solution injected into the instrument enters a gas stream which transports the sample into a separation tube known as the "column." (Helium or nitrogen is used as the so-called carrier gas.) The various components are separated inside the column.

  Applications
  User Instructions
NUCON 5765 GAS CHROMATOGRAPH is advance version with Microprocessor Temperature Controller with Multi Ramp Temperature Programming, Auto Cooling making it possible to operate 10 degree C above ambient for special applications like NEPTHA. Microprocessor Temperature Controller with Multi Ramp Temperature Programming, Auto Cooling making it possible to operate 10 degree C above ambient

  Contact Us
Contact No. 0161-2313101
Email Id ciphetludhiana1989@gmail.com

  GAS CHROMATOGRAPH Charges
Procedure Name
Industry
University
National LAB/R&D
Remark
Director, ICAR-CIPHET
750
600
650
Per Sample

Additional Rs 100/-towards postal charges if result are to be posted
The Demand Draft should be in favour of ""
Letter, DD & Samples send to ""