Instrument Details
Instrument/Facility Name: Inductively Couple Plasma-Optical Emission Spectrophotometer- ICP-OES
Make                                   : Agilent Technologies
Model                                  : Agilent 5110 ICP-OES
Specification   :Simutaneous quantitative analysis of multiple elements

Click to ViewWave length range: 160-900 nm Wavelength accuracy: <0.4 pm Spectral resolution: 0.002 nm at 200 nm. Resolution: 1:145000 Echelle grating with large blaze angle (760) Dual view Plus plasma observation for 2+2 plasma view Peltier cooled CCD array detector with high quantum efficiency, increased UV-sensitivity and reduced warm-up times Free-running 40 MHz g generator with solid state power supply for long term plasma stability and for excellent reproducibility.

  Working Principles
Click to ViewInductively Coupled Plasma Optical Emission Spectrophotometer is a Multielement analysis technique based on optical emission spectrometry. When plasma energy is given to an analysis sample from outside, the component elements (atoms) are excited. When the excited atoms return to low energy position, emission rays (spectrum rays) are released and the emission rays that correspond to the photon wavelength are measured by detector. To generate plasma, argon gas is supplied to torch coil, and high frequency electric current is applied to the work coil at the tip of the torch tube. Using the electromagnetic field created in the torch tube by the high frequency current, argon gas is ionized and plasma is generated. This plasma has high electron density and temperature (10000K) and this energy is used in the excitation-emission of the sample. Solution samples are introduced into the plasma in an atomized state through the narrow tube in the canter of the torch tube.

  Applications
  User Instructions
ICP-OES can be used in both qualitative and quantitative analysis for soil, water, sediments and crop straw and grain macro and micronutrient. • Qualitative and quantitative data can be provided, • All sample should be filtered through 0.2 µm filter. • Samples should not be toxic or hazardous. Quantitative analysis of Ca, K, Fe, Mg, Na, Ag, Al, As, Ba, Be, Cd, Co, Cu, Mn, Mg, Mo, Ni, Sb, Pb, Se, Th, V, Zn and Cr.

  Contact Us
Contact No. 05962-230208
Email Id director.vpkas@icar.gov.in

  Inductively Couple Plasma-Optical Emission Spectrophotometer- ICP-OES Charges
Procedure Name
Industry
University
National LAB/R&D
Remark
Total Soil or plants and compost micronutrients like Ca, K, Fe, Mg, Na, Ag, Al, As, Ba, Be, Cd, Co, Cu, Mn, Mg, Mo, Ni, Sb, Pb, Se, Th, V, Zn and Cr.
1000
1000
1000
Rs 1000 for each element

Additional Rs 100/-towards postal charges if result are to be posted
The Demand Draft should be in favour of "Director, ICAR-VPKAS, Almora"
Letter, DD & Samples send to "Director, ICAR-VPKAS, Almora"