Indian Council of Agricultural Research
(Agricultural Knowledge Management Information System)


ICAR-National Institute of Abiotic Stress Management, Malegaon, Baramati-413115, Pune, Maharashtra (www.niam.res.in)
Click Here to See Management Committee
Instrument Details
Instrument/Facility Name: Inductively Coupled Plasma Mass Spectrometry (ICPMS)
Make                                   : Agilent Technologies
Model                                  : 7700 Series ICP-MS
Specification   :New ORS3 Collision/Reaction Cell: X Longer, narrower rods, higher cell pressure and frequency – MUCH better performance in He mode; New RF Generator: Fast tuning 27MHz generator, for better tolerance to changing matrix (incl. organics) ; Increased Matrix Tolerance X : High Matrix Introduction (HMI) standard on 7700x model Much smaller cabinet; >30% smaller footprint than any other ICP‐MS Simple software; reliable Auto‐Tuning ; MassHunter software – intuitive and easy to learn. Pre‐set plasma conditions and fast lens auto‐tuning

Click to View Low‐flow (typically 0.15mL/min)  Temperature stabilized (Peltier cooled sp y ra chamber)  Wide Torch Injector ID (2.5mm)  No O‐rings in spray chamber end‐ cap – reduced reduced risk of contamination contamination  Auto‐alignment of torch after maintenance  Fast frequency‐matching RF generator  Simple setup, using “pre‐set” plasma conditions and auto‐tuning  Quantification range better than 1 ppt

  Working Principles
Click to ViewInductively coupled plasma mass spectrometry (ICPMS) is an analytical instrument used for elemental determination. The sampled material is introduced into high-energy argon plasma that consists of electrons and positively charged argon ion. In the plasma, the material is split into individual atoms. These atoms will lose electrons and become (singly) charged positive ions. To allow their identification, the elemental ions produced in the plasma (ICP) must be transferred from 7000 K to room temperature and from atmospheric pressure to high vacuum. To do so, the ions are extracted through a number of apertures. Besides ions also photons are produced in the plasma.

  Applications
  User Instructions
Key applications are: Environmental • Foods • Semiconductor • Clinical • Chemical/Petrochemical • Pharmaceutical • Consumer Goods • Forensic • Geological • Nuclear • Academic/Research1. There should be minimum 5 samples with at least 3 elements in each sample for analysis 2. Biological and non-biological samples can analyses 3. In case of liquid sample minimum 25 ml is required for processing

  Contact Us
Contact No. 02112-254057/8
Email Id director.niasm@icar.gov.in

  Inductively Coupled Plasma Mass Spectrometry (ICPMS) Charges
Procedure Name
Industry
University
National LAB/R&D
Remark
Fish tissues samples/Soil/water samples/Plant samples/Blood samples
500
300
200
GST as applicable. There should be minimum 5 samples with at least 3 elements in each sample for analysis

Additional Rs 100/-towards postal charges if result are to be posted
The Demand Draft should be in favour of "ICAR Unit NIASM"
Letter, DD & Samples send to "ICAR-National Institute of Abiotic Stress Management, Malegaon Khurd, Baramati-413115, Pune, MH"