Instrument Details
Instrument/Facility Name: Infrared Thermometer
Make                                   : Everest Interscience Inc
Model                                  : Agri-Therm III (Model: 6210L)
Specification   :

Click to ViewTemperature measurement • Scale range: ¬40°c to 100°c • Resolution: 0.1°c • Accuracy: ±0.25°c from 0°c to 50°c & ±0.5°c from ¬40°c to 0°c or 50°c to 100°c • Repeatability: ±0.1°c • Temperature: all functions in °c, corresponding to voltage output • Temperature measurement modes: surface temperature, ambient dry bulb temperature and temperature differential Optical considerations • Spectral pass band: 8 < wavelengths < 14 microns • Sighting: TTL/SLR intra¬optical light sighting: visible light illuminates field of view • Field of view: variable from 4° down to 2 mm with vario¬zooom™ fieldvariable¬focus • Display: numeric liquid crystal display on rear panel

  Working Principles
Click to ViewInfrared thermometers work based on black body radiation, According to which any material with a temperature above absolute zero has molecules moving within it. The higher the temperature, the faster the molecules move. The molecules emit infrared radiation as they move, and emit more radiation, including visible light, as they get hotter. This is why a heated metal emits a red or white glow. Infrared thermometers detect and measure this radiation. Infrared light can be focused, reflected or absorbed like visible light. Infrared thermometers employ a lens to focus infrared light from an object onto a detector known as a thermopile. The function of the thermopile is to absorb infrared radiation and convert it to heat. The thermopile gets hotter as it absorbs more and more infrared energy. The excess heat is converted into electricity, which is transmitted to a detector which determines the temperature of the object.

  Applications
  User Instructions
As per user manual of Agri-Therm III (Model: 6210L)

  Contact Us
Contact No. 02112-254057/8
Email Id director.niasm@icar.gov.in

  Infrared Thermometer Charges
Procedure Name
Industry
University
National LAB/R&D
Remark
Samples per day
2500
1000
1500
+ GST as applicable

Additional Rs 100/-towards postal charges if result are to be posted
The Demand Draft should be in favour of "ICAR Unit NIASM"
Letter, DD & Samples send to "ICAR-National Institute of Abiotic Stress Management, Malegaon Khurd, Baramati-413115, Pune, MH "